In 2018 the technical-commercial alliance for electrical conductors was made effective by means of Superintendencia de Electricidad y Combustibles in a legal documents in Chile and Perú (exempt resolution #24429 and #22312) witch authorize INGCER Certification Body to use test reports from the CEIS laboratory.
CEIS is a testing, innovation and service centre with extensive technical experience in the field of conformity assessment as well as in the development and performance of tests and technical assistance services related to Quality, Safety and the Environment. CEIS is accredited by ENAC in accordance with the UNE/EN/ISO/IEC 17025 standard.
INGCER CERTIFICATION BODY and CEIS are projected as a link that interconnects the exports of electrical conductors to chilean and peruvian market.

We remind that the Peruvian Technical Regulation approved with Supreme Decree Nº 013-2016-PRODUCE defines that the ever product (electrical conductor) that are regulated under this regulation can use certificates issued by bodies accredited by the authority of the country where are approve.
The following is a list of products from the drivers' area linked to this alliance:
NAME | TESTING PROTOCOL | INTERNATIONAL STANDARD |
H07V-U | SP 2/04 | IEC 60227-3:1997IEC 60227-1:2007 IEC 60228:2004 IEC 60228-1-1:2004 IEC 60332-1-2:2004 IEC 60332-1-3:2004 |
H07V-R | EP 2/05 | IEC 60227-3:1997 IEC 60227-1:2007 IEC 60228:2004 IEC 60332-1-1:2004 IEC 60332-1-2:2004 IEC 60332-1-3:2004 |
H07V-K | EP 2/06 | IEC 60227-3:1997 IEC 60227-1:2007 IEC 60228:2004 IEC 60332-1-1:2004 IEC 60332-1-2:2004 IEC 60332-1-3:2004 |
H03VV-F | SP 2/7 | IEC 60227-5:2003 IEC 60227-1:2007 IEC 60228:2004 IEC 60332-1-1:2004 IEC 60332-1-2:2004 IEC 60332-1-3:2004 |
H05VV-F, H05VVH2-F | SP 2/8 | IEC 60227-5:2003 IEC 60227-1:2007 IEC 60332-1-1:2004 IEC 60332-1-2:2004 IEC 60332-1-3:2004 |
H05RR-F | SP 2/9 | IEC 60245-4:2004 IEC 60245-1:2008 IEC 60228:2004 |
H05RN-F | EP 2/10 | IEC 60245-4:2004 IEC 60245-1:2008 IEC 60228:2004 |
H07RN-F | EP 1/11 | IEC 60245-4:2004 IEC 60245-1:2008 IEC 60228:2004 |
EQUITY | EP 2/14 | IEC 60502-1:2009 IEC 60332-1-3:2004 IEC 60228:2004 IEC 60332-1-1:2004 IEC 60332-1-2:2004 |
RV-K | EP 2/15 | IEC 60502-1:2009 IEC 60228:2004 IEC 60332-1-1:2004 IEC 60332-1-2:2004 IEC 60332-1-3:2004 |
RZ1 | EP 2/16 | IEC 60502-1:2009 IEC 60228:2004 IEC 60332-1:2004 IEC 60332-3-24:2008 IEC 61034-2:2005 IEC 60754-1:1994 IEC 60754-2:1997 IEC 60684-2:2005 |
RZ1-K | EP 2/17 | IEC 60502-1:2009 IEC 60228:2004 IEC 60332-1:2004 IEC 60332-3-24:2008 IEC 61034-2:2005 IEC 60754-1:1994 IEC 60754-2:1997 IEC 60684-2:2005 |
H07Z1-U | EP 2/18 | UNE 211002:2008 IEC 60332-1-2:2004 IEC 60332-3-24:2008 IEC 61034-2:2005 IEC 60754-1:1994 IEC 60754-2:1997 IEC 60684-2:2005 |
H07Z1-R | EP 2/19 | UNE 211002:2008 IEC 60332-1-2:2004 IEC 60332-3-24:2008 IEC 61034-2:2005 IEC 60754-1:1994 IEC 60754-2:1997 IEC 60684-2:2005 |
H07Z1-K | EP 2/20 | UNE 211002:2008 IEC 60332-1-2:2004 IEC 60332-3-24:2008 IEC 61034-2:2005 IEC 60754-1:1994 IEC 60754-2:1997 IEC 60684-2:2005 |
References:
REX 24429 Authorizes INGCER Organism to use CEIS test reports in the drivers area
REX 22312 Authorizes INGCER Organism to use CEIS test reports in the drivers area.